This is a sample. The practice below is fictional; the structure, depth, and methodology are exactly what your practice receives.
Confidential — for internal compliance records
HIPAA Security Risk Assessment
- Prepared for:
- Riverside Pediatrics of Bergen County (fictional sample practice)
- Prepared by:
- Practice All — Healthcare IT Services, Bergen County, NJ
- Assessment period:
- August 4–8, 2026
- Report date:
- August 11, 2026
- Scope:
- 1 location · 3 providers · 8 staff · 11 workstations
- Next review due:
- August 2027 (or upon material change)
1. Executive summary
Riverside Pediatrics operates a modern cloud EHR and a generally well-run office, but the assessment identified 2 critical, 2 high, 3 medium, and 1 low-severity findings across the administrative, physical, and technical safeguards of the HIPAA Security Rule. The two critical findings — remote EHR access without multi-factor authentication and the absence of any ransomware-resilient backup — represented the most plausible paths to a reportable breach and were remediated during the engagement, together with the shared front-desk login.
With the included fixes applied, the practice’s residual risk is concentrated in aging workstations and missing vendor agreements, both addressable within 30 days at modest cost. Completing the 30/60/90-day roadmap in Section 5 would place the practice in a defensible, attestation-ready posture ahead of the proposed Security Rule updates.
2
Critical2
High3
Medium1
Low2. Scope and methodology
This assessment follows the process described in NIST SP 800-30 and OCR’s Guidance on Risk Analysis, mapping each observation to the implementation specifications of the HIPAA Security Rule (45 CFR Part 164, Subpart C). Evidence was gathered through a structured interview with the practice administrator, a guided questionnaire completed by the office manager, an authorized technical scan of the internal network and all workstations, a review of EHR user and audit-log configuration, and inspection of vendor contracts and policies provided by the practice.
Systems in scope: cloud EHR (vendor-hosted), practice management and billing workspace, local file server, 11 workstations and 2 laptops, network equipment, document scanner, one networked clinical device, e-fax, email, and the after-hours answering service. Out of scope: the EHR vendor’s internal controls (covered by their BAA and SOC 2 report, which were verified as current).
3. Risk rating methodology
Each finding is rated by likelihood (the probability of the threat exploiting the vulnerability in the next 12 months, given current controls) and impact (effect on confidentiality, integrity, and availability of ePHI, plus operational and regulatory consequences). Severity is the product of the two:
| Likelihood ↓ / Impact → | Low | Medium | High |
|---|---|---|---|
| High | Medium | High | Critical |
| Medium | Low | Medium | High / Critical* |
| Low | Low | Low / Medium | Medium |
*Elevated to Critical where the finding removes the practice’s ability to recover (e.g., backup failures).
4. Findings (8)
| ID | Finding | Severity | Status |
|---|---|---|---|
| F-01 | Remote access to the EHR without multi-factor authentication | Critical | Remediated ✓ |
| F-02 | No offline or immutable copy of critical data | Critical | Remediated ✓ |
| F-03 | Windows 10 workstations past end of support | High | Open |
| F-04 | Shared login used by front-desk staff | High | Remediated ✓ |
| F-05 | Business associate agreements missing for two vendors | Medium | Open |
| F-06 | No documented security awareness training | Medium | Open |
| F-07 | Guest Wi-Fi shares a network with clinical devices | Medium | Open |
| F-08 | Contingency plan exists but has never been tested | Low | Open |
Remote access to the EHR without multi-factor authentication
HIPAA safeguard: §164.312(a)(2)(i) — Access Control: Unique User Identification; §164.312(d) — Person or Entity Authentication
- Observation
- Providers and the billing team access the cloud EHR from home using username and password only. MFA is available from the vendor but has never been enabled. Two staff passwords were found in a public credential-breach database.
- Risk
- A single reused or phished password gives an attacker full access to every patient chart. Credential attacks are the leading cause of reported healthcare breaches.
- Recommendation
- Enable vendor MFA for all user accounts (app-based, not SMS, for providers). Enforce a password manager for staff. Review EHR access logs for unfamiliar sign-in locations over the past 90 days.
- Status
- REMEDIATED during assessment (included fix 1 of 3)
No offline or immutable copy of critical data
HIPAA safeguard: §164.308(a)(7)(ii)(A) — Data Backup Plan; §164.310(d)(2)(iv) — Data Backup and Storage
- Observation
- The practice management database and shared documents are backed up nightly to a USB drive that remains permanently connected to the server. No backup has been test-restored in the last 12 months. The EHR vendor's backup covers only the hosted chart data.
- Risk
- Ransomware routinely encrypts connected backup drives along with the systems they protect. In that scenario the practice would lose scheduling, billing workspace, scanned documents, and HR records with no recovery path.
- Recommendation
- Implement a 3-2-1 backup: local copy, encrypted cloud copy with immutability/versioning, and a quarterly test restore with a written result. Document recovery time objectives in the contingency plan.
- Status
- REMEDIATED during assessment (included fix 2 of 3)
Windows 10 workstations past end of support
HIPAA safeguard: §164.308(a)(1)(ii)(B) — Risk Management; §164.312(c)(1) — Integrity
- Observation
- Six of eleven workstations run Windows 10, which stopped receiving security updates in October 2025. Two of them are used at the front desk to access the EHR and scan patient documents.
- Risk
- Unpatched operating systems accumulate publicly known vulnerabilities that commodity malware exploits automatically — no targeted attack required.
- Recommendation
- Replace or upgrade all six devices within 60 days (four support Windows 11; two require replacement). Until then, restrict those machines from email and web browsing.
- Status
- Open — scheduled in roadmap (30-day items)
Shared login used by front-desk staff
HIPAA safeguard: §164.312(a)(2)(i) — Unique User Identification; §164.308(a)(5)(ii)(C) — Log-in Monitoring
- Observation
- Three front-desk employees share a single "FrontDesk" Windows and EHR account. Individual activity cannot be attributed to a specific person.
- Risk
- Without unique identification, the practice cannot investigate suspicious chart access, satisfy an OCR audit request, or cleanly terminate access when an employee leaves.
- Recommendation
- Create individual accounts for each employee, remove the shared account, and enable automatic logoff on front-desk machines (§164.312(a)(2)(iii)).
- Status
- REMEDIATED during assessment (included fix 3 of 3)
Business associate agreements missing for two vendors
HIPAA safeguard: §164.308(b)(1) — Business Associate Contracts; §164.314(a) — Organizational Requirements
- Observation
- The practice could not produce BAAs for its e-fax provider or its after-hours answering service, both of which handle PHI. BAAs are in place for the EHR, clearinghouse, and email provider.
- Risk
- Sharing PHI with a vendor without a BAA is itself a HIPAA violation, independent of any breach, and has been the basis of OCR enforcement actions against small practices.
- Recommendation
- Execute BAAs with both vendors within 30 days or migrate to equivalents that will sign one. Add a BAA checklist step to the new-vendor process.
- Status
- Open — templates provided (30-day items)
No documented security awareness training
HIPAA safeguard: §164.308(a)(5)(i) — Security Awareness and Training
- Observation
- Staff receive informal guidance at hire but no recurring security training, and no training records are kept. Two of five staff clicked a simulated phishing link during the assessment.
- Risk
- Phishing remains the most common initial access vector in healthcare incidents. Undocumented training also weakens the practice's defensibility in an audit.
- Recommendation
- Adopt brief quarterly training with phishing simulation and automatic record-keeping. Include it in onboarding for new hires.
- Status
- Open — scheduled in roadmap (60-day items)
Guest Wi-Fi shares a network with clinical devices
HIPAA safeguard: §164.312(e)(1) — Transmission Security
- Observation
- The waiting-room guest Wi-Fi is served from the same flat network as workstations, the document scanner, and a networked spirometer. Patient devices can see clinical devices on the LAN.
- Risk
- Any compromised or malicious patient device gains a network path to clinical systems, bypassing the firewall entirely.
- Recommendation
- Segment guest traffic onto an isolated VLAN with client isolation. Inventory all networked clinical devices while segmenting (supports the proposed Security Rule asset-inventory requirement).
- Status
- Open — scheduled in roadmap (60-day items)
Contingency plan exists but has never been tested
HIPAA safeguard: §164.308(a)(7)(ii)(D) — Testing and Revision Procedures
- Observation
- A written contingency plan from 2022 names a former employee as the emergency contact and references a server that has since been retired. It has never been exercised.
- Risk
- In a real outage the plan would misdirect staff during the hours that matter most, extending downtime and potentially patient-care disruption.
- Recommendation
- Update roles and systems, then run a 60-minute tabletop exercise annually. Keep a printed copy accessible without network access.
- Status
- Open — scheduled in roadmap (90-day items)
5. Remediation roadmap
Within 30 days
- Replace/upgrade the six end-of-support workstations (F-03)
- Execute BAAs with e-fax and answering-service vendors (F-05)
- Enable automatic screen lock (10 min) on all workstations
- Review EHR audit logs for the past 90 days of remote sign-ins
Within 60 days
- Launch quarterly security awareness training with phishing simulation (F-06)
- Segment guest Wi-Fi onto an isolated VLAN; inventory clinical devices (F-07)
- Enable full-disk encryption on the two laptops used for home charting
Within 90 days
- Update and tabletop-test the contingency plan (F-08)
- Adopt a sanction policy and access-review calendar (annual)
- Schedule the next risk assessment review (12 months)
6. Attestation record
This document records that Riverside Pediatrics of Bergen County conducted an accurate and thorough assessment of the potential risks and vulnerabilities to the confidentiality, integrity, and availability of electronic protected health information held by the practice, as required by 45 CFR §164.308(a)(1)(ii)(A), for the period noted on the cover. Findings and remediation status are documented herein; the remediation roadmap constitutes the practice’s risk management plan under §164.308(a)(1)(ii)(B).
Practice representative — signature / date
Assessor, Practice All — signature / date
This report, for your practice, in five business days